Our well-equipped facilities and exceptional good quality manage throughout all stages of production enables us to guarantee total shopper satisfaction for How To Test A Thermal Fuse, thermal fuse trader, Xiamen Temperature Fuse, Striving hard to attain continual success based on quality, reliability, integrity, and complete understanding of market dynamics.
Factory directly VDE Thermal Fuse - ALLOY TCO – A series – A-3A-F – Aupo Detail:

Model No |
a |
b |
c |
d |
e |
A-3A-F |
6.2 ± 0.5 |
6.3 ± 0.5 |
2.5 ± 0.3 |
Φ0.6 ±0.02 |
70 ± 3 |
Model NO.
|
Tf(℃)
|
Fusing-off Temperature (℃)
|
Th(℃)
|
Tm(℃)
|
Ir(A)
|
Ur(V)
|
IEC
|
Corp
|
A0-3A-F
|
84℃
|
84+0/-10
|
82±2
|
65
|
203
|
2
|
250
|
A1-3A-F
|
102℃
|
102+0/-10
|
98±2
|
80
|
203
|
2
|
250
|
A2-3A-F
|
115℃
|
115+0/-10
|
112±3
|
99
|
203
|
2
|
250
|
A3-3A-F
|
125℃
|
125+0/-10
|
120±3
|
105
|
203
|
2
|
250
|
A4-3A-F
|
130℃
|
130+0/-10
|
126±2
|
107
|
203
|
2
|
250
|
A5-3A-F
|
135℃
|
135+0/-10
|
131±3
|
115
|
203
|
2
|
250
|
A7-3A-F
|
138℃
|
138+0/-10
|
135±2
|
118
|
203
|
2
|
250
|
A12-3A-F
|
145℃
|
145+0/-10
|
140±2
|
126
|
203
|
2
|
250
|
A8-3A-F
|
150℃
|
150+0/-10
|
145±3
|
128
|
203
|
2
|
250
|
A16-3A-F
|
160℃
|
160+0/-10
|
155±2
|
140
|
203
|
2
|
250
|
Model No. |
UL/CUL |
VDE |
CCC |
PSE |
KTL |
A0-3A-F |
E140847 |
40008720 |
○ |
JET0749-32001-1005 |
SU05017-17001 |
A1-3A-F |
2009010205372876 |
JET0749-32001-1003 |
SU05017-17002 |
A2-3A-F |
A3-3A-F |
JET0749-32001-1004 |
SU05017-17003 |
A4-3A-F |
A5-3A-F |
A7-3A-F |
A8-3A-F |
JET0749-32001-1006 |
A12-3A-F |
○ |
A16-3A-F |
○ |
|
|
|
|
|
○ pending
|
Product Description:
- AUPO A-series thermal fuse is non-resettable thermal protection device with plastic casing, which is sensitive to the ambient temperature, with accurate and stable operating temperature, small size and sealed structure.

- Alloy type A-series thermal fuse: when ambient temperature rises to its operating temperature, the fusible alloy will melt and shrink into bulb on both sides of pin, with the help of surface tension and special resin, cut off the circuit permanently.
Advantages:
- 1. Confidential alloy formula technology to ensure stable operation and high precision.
- 2. Complete product quality management system to ensure high consistency and reliability.
- 3. Plastic case, good insulation, easy to install.
- 4. Epoxy resin package, good product sealing.
Application Field:
- A-series products are widely used for overheating protection of all kinds of transformer coils, as well as surge protection of various power supplies and plugs.
Product Certification:
- A-series products meet the safety test requirements of IEC 60691 Ed 4.0 and GB/T 9816.2013, and many models are certified with UL, VDE, CCC, PSE, KC, TUV and other safety approvals.
Product detail pictures:
Related Product Guide:
Dedicated to strict quality control and thoughtful customer service, our experienced staff members are always available to discuss your requirements and ensure full customer satisfaction for Factory directly VDE Thermal Fuse - ALLOY TCO – A series – A-3A-F – Aupo , The product will supply to all over the world, such as: Macedonia, Suriname, Ecuador, We have sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
By Molly from Paraguay - 2017.10.25 15:53
It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
By Alan from Tanzania - 2017.05.21 12:31